Page 5 - Ketterer – Brochure Motor Drives and Spindle Drives
P. 5

 Ø5.2
75.7 39.9
25.7
25.2 14.2
    Pin assignment
View A 123
654
Technical notes
▪ The drive requires a suitable 12 V controller.
▪ The drive working range (nominal torque) is determined for a service life of 10,000 double strokes.
▪ By using a controller with a short-circuit brake the holding torque position of the drive can be increased.
Mounting example:
Screw M5x20 DIN 7380 (3x)
Ø45
40
A
  1. Motor black - 2. Motor blue +
3. Hall sensor red +5V
4. Hall sensor violet, output 2 5. Hall sensor black -
6. Hall sensor green, output 1
0,75 mm2
PIN type AMP170364
  0,25 - 0,35 mm2 PIN type AMP170363
  Technical data for motor drive 3112 in combination with spindle unit 3130.14
 with 3130.14-V1XEXXXHXXX
with 3130.14-V2XEXXXHXXX
 Type of spindle
Duty cycle nominal load* & Stroke 500 mm
Max. lifting force F1* Max. pulling force F2*
Stat. self locking
TR14x3 RH
90 s ON/ 540 s OFF
900 N 500 N 150 kg
SG14x16P4 RH 25 s ON/ 300 s OFF
400 N 400 N 60 kg
              * Load determined for service life of 10,000 double strokes
www.ketterer.de
25
   33°
7.4
Ø62.5
5.2
17°
Cable length 100 incl. connector
118.5 141
149.4
ø19
1.6
Gear Motors
hex 6/9
 
















































   3   4   5   6   7