Page 27 - Ketterer – Brochure Lifting Units
P. 27

 4115.00-V02EXXXMXXX Gear head 3039
Z
Y
7.6
14.4
Variante V01
30
Technical notes
Variante V02
35.8
ø3.4 (2x)
24
H1
ø4.6 max.7 deep (4x)
ø4.1 (4x)
H1
12
44 M
E
ø4.1 (2x through going)
4115.00-V01EXXXMXXX Gear head 3045
7
22
27
55
View Z
View Y
ø20
▪ The lifting units must be protected against lateral forces by a separate guide system.
▪ Attention: The spindle systems with a spindle pitch > 3mm may not be self-locking. Check the self-locking effect in the application.
▪ The lifting unit is only pressure loadable.
www.ketterer.de
▪ Incorrect dimensioning of the guide system can damage the lifting unit: Please note the design and safety instructions for spindle drives. You will find them at: https:// www.ketterer.de/en/ downloads/instructions
E + 2x H1
4.5
ø10 7
ø42
30
35.8
ø4.9
ø25 ø29
hex7
hex 6.25
Lifting Units
45°
45°
29 27




















































   25   26   27   28   29